/TEST PROGRAM FOR DM8E40 MEMORY MANAGEMENT BOARD
/       E. LOPES CARDOZO
/       WESTVRIES COMPUTER CONSULTING BV
/       RIJKSSTRAATWEG 19A
/       1969 LB HEEMSKERK
/       02510 - 43244

/SYMBOL DEFINITIONS:
SINT=6254
SUF=6274
CINT=6204
CUF=6264
RTM=6205
LTM=6235
LRM=6245
SMME=6265
CMME=6275
SKME=6215
SKMM=6225

/FOR PRODUCTION TEST DEFINE PRODUCTION:
         /PRODUCTION=0

/INTERRUPT SERVICE ROUTINE:
         *0
	0
	JMP SERV

       *20
SERV,	DCA AC           /SAVE AC
	SINT             /TRAP ?
	JMP INTERR       /NO, ILLEGAL INTERRUPT
	CINT             /CLEAR TRAP FLAG
	RTM              /READ TRAP REGISTER
	DCA TRAPD         /THAT IS THE INSTR. THE HARDWARE SAW
	CLA CMA
	TAD 0
	DCA 0            /BACKUP PC
	TAD I 0                  /GET TRAPPED INSTRUCTION FROM MEMORY
	CIA              /AND COMPARE TO
	TAD TRAPD         /TRAP REGISTER CONTENTS
	SZA CLA                  /SHOULD BE EQUAL
	JMS TRPERR       /ERROR IN TRAP REGISTER
	TAD 0            /DID WE TRAP THE SAFETY HLT ?
	TAD (-HALT        /
	SZA CLA                  /?
	CMA             /NO, SET AC=-1
	JMP I ENDTRP      /BACK TO MAIN LOOP
ENDTRP,	.-1              /CONTINUATION ADDRESS

/VIRTUAL CODE SEQUENCES:
RELTST,	TAD I (7000    /RELOCATION TEST; GET DATAFIELD
	JMP HALT       /EXIT FROM USER MODE

TRPTST,	JMP .          /GETS IOT TO BE TESTED
	JMP .+2                /FOR CIF: ENABLE INTERRUPTS
	ION            /FOR SKON: REENABLE INTERRUPTS
HALT,	HLT            /EXIT FROM USER MODE
	JMP .          /*** IF HERE, HLT DID NOT TRAP ***
TTYTST,	TAD BELL        /TEST TTY IN UNTRAPED MODE
	TLS            /SEND A BELL TO THE CONSOLE
	TSF            /WAIT TILL READY
	JMP .-1                /
IFNDEF PRODUCTION <
                       CLA/ >
IFDEF PRODUCTION <
	KCC            /USED TO CLEAR THE AC
	SZA            /DIDITDO ?
	JMP .         /NO !!! *** UNTRAPPED KCC DID NOT CLA ***
	TCF            /EXIT WITH TTY FLAG CLEAR
	TSF            /DID THAT WORK ?
	SKP            /YES
	JMP .          /***TCF DID NOT CLEAR FLAG *** >
	JMP HALT        /NOW EXIT FROM USER MODE

/MD-LINE TEST:
MDTST,	DCA I (Q
	TAD I (Q
	IAC
	SZA            /TEST ALL 4096 VALUES
	JMP MDTST
	JMP HALT
Q,	0

/CDTOIF TEST ROUTINE
CDTF,	0
	6200           /CDTOIF
	CIF 0
	JMP I CDTF

/RDF TEST ROUTINE:
TSTRDF,	RDF
KK,	TAD K0         /GET ACTUAL FIELD NUMBER
	JMP HALT        /GOT THROUGH

K0,	0
K1,	1
K2,	2
K3,	3
K4,	4
K5,	5
K6,	6
K7,	7

/VARIABLES, COUNTERS AND POINTERS:
COUNT,	0
COUNT1,	0
COUNT2,	0
COUNT3,	0
PTR,	0
FIELDS,	0      /NUMBER OF FIELDS AVAILABLE
AC,	0
TRAPD,	0
BELL,	207

PAGE
	JMS INIT           /SETUP FIELDS
START,	CAF
	KIE           /DISABLE KEYBOARD INTERRUPTS
LOOP0,	JMS COPY        /MOVE PAGE 0 TO ALL FIELDS
	JMS IOTTST     /STATIC TEST OF DM8E40 IOTS
	TAD FIELDS
	CIA
	DCA COUNT      /FOR ALL FIELDS
	TAD (CDF
	DCA FCDF       /SET A CDF TO EACH FIELD
LOOP1,	TAD COUNT        /
	TAD FIELDS
FCDF,	CDF 0         //CDF0, CDF10, CDF 20, ...
	DCA I (7000    //PUT THE FIELD NUMBER AT 7000
	CDF 0         //RESTORE THE DATAFIELD
	TAD FCDF       /MAKE A NEW CDF
	TAD (10
	DCA FCDF       /
	ISZ COUNT      /ALL FIELDS DONE
	JMP LOOP1     /
/NOW A SIMPLE RELOCATION TEST. WE SET UP A SEQUENCE OF
/RELOCATION AND THAN GO VIRTUAL, PICK UP THE FIELD
/CONSTANT FROM 7000 AND HLT, TO GET OUT OF USER MODE
/WE TRY TO TEST IF ALL WORDS OF THE RELOCATION RAM
/CAN TAKE ALL VALUES, AT LEAST ALL VALUES FOR WHICH
/THERE ARE FIELDS IN THE SYSTEM.
	TAD (RET1      /SETUP TRAP RETURN ADDRESS
	DCA ENDTRP     /
	TAD FIELDS     /SET UP COUNTER FOR FIELDS
	CIA
	DCA COUNT      /
LOOP2,	TAD (-10         /TEST ALL 8 WORDS OF THE RELOCATION RAM
	DCA COUNT1     /
LOOP3,	TAD (-10         /LOAD ALL WORDS OF THE RAM
	DCA COUNT2     /
LOOP4,	TAD COUNT2       /
	TAD (10               /MAKE 0, 1, 2, ...
	LRM           /SET ALL WORDS TO 0
	ISZ COUNT2     /
	JMP LOOP4     /
	TAD COUNT      /
	TAD FIELDS     /POSITIVE REAL FIELD #
	CLL RTL               /
	RAL           /SHIFT TO BITS 6-8
	TAD COUNT1     /ADD VIRTUAL FIELD #
	TAD (10               /(POSITIVE)
	LRM           /THIS SETS ONE WORD
	TAD COUNT1     /
	TAD (10               /
	TAD (100       /USER MODE+VIRTUAL DATA FIELD
	RTF           /RESTORE FLAGS
	CLA           /?!
	JMP RELTST     /JMP TO RELOCATION TEST
/RELTST MUST BE AVAILABLE IN EACH FIELD
RET1,	CLA
	TAD AC        /GET AC FROM TRAP
	CIA           /AND COMPARE TO INTENDED FIELD #
	TAD COUNT      /
	TAD FIELDS     /
	SZA CLA               /
	JMS RELERR    /RELOCATION ERROR
	ISZ COUNT1     /
	JMP LOOP3     /
	ISZ COUNT      /
	JMP LOOP2     /
/END OF RELOCATION TEST. NOW COMES THE TRAP/UNTRAP TEST
/IN EACH AVAILABLE FIELD WE TEST EACH IOT FROM THE TABLE
	TAD FIELDS     /
	CIA
	DCA COUNT      /
LOOP5,	TAD (-10
	DCA COUNT1     /ZERO THE RELOCATION RAM
LOOP6,	TAD COUNT        /
	TAD FIELDS     /
	CLL RTL
	RAL           /
	TAD COUNT1     /
	TAD (10               /MAKE ONE-TO-ONE MAPPING
	LRM           /LOAD RELOCATION MEMORY
	ISZ COUNT1     /
	JMP LOOP6     /
	TAD COUNT      /
	TAD FIELDS     /
	CLL RTL
	RAL           /
	TAD (CDF       /MAKE CDF
	DCA XCDF       /CDF TO TARGET FIELD
	TAD (TABLE     /SETP POINTER FOR IOT TABLE
	DCA PTR               /
LOOP7,	TAD I PTR        /
	DCA TRPTST     /DROP IT IN THE TRAPTEST
	TAD (RET2
	DCA ENDTRP
	TAD TRPTST     /
XCDF,	CDF           /CDF TARGET FIELD
	DCA I (TRPTST /IN THE TARGET FIELD TOO
	CDF 0         /
	JMS UTRALL     /UNTRAP ALL DEVICE CODES
	TAD TRPTST     /GET TEST IOT AGAIN
	AND (7776      /CLEAR UNTRAP BIT
	LTM           /AND SET DM8E40 TO TRAP FOR THIS IOT
	SUF           /ENTER USER MODE
	ION           /WITH INTERRUPT ON
	JMP TRPTST     /THIS BRINGS US INTHE TARGET FIELD !
/- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
RET2,	ISZ PTR               /RETURN FROM TRAP HANDLER
	TAD I PTR      /GET TRAP/UNTRAP INDICATOR
	RAR           /BIT 11 IS XOR!
	SZL CLA               /OK ?
	JMS TERROR    /TRAP ERROR
	TAD (RET3
	DCA ENDTRP     /SET NEW RETURN POINT
	JMS TRPALL     /TRAP ALL DEVICE CODES
	TAD TRPTST
	AND (7776
	IAC           /SET UNTRBP BIT
	LTM           /
	SUF
	ION
	JMP TRPTST     /GO !

PAGE
/- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
RET3,	ISZ PTR
	TAD I PTR
	RAR           /BIT 11 DOES XOR
	SZL CLA               /OK ?
	JMS UERROR    /NO, UNTRAP ERROR
	ISZ PTR               /SELECT NEXT IOT
	TAD I PTR      /AND FETCH IT
	SZA CLA               /END OF LIST ?
	JMP LOOP7     /NO, TEST NEXT IOT
IFNDEF FYSIOL <
/FINALY, WE TEST THE CONSOLE TERMINAL WITH IT'S IOTS UNTRAPPED:
	TAD (RET4
	DCA ENDTRP
	JMS TRPALL     /TRAP ALL DEVICE CODES,
	TAD (6031      /EXCEPT FOR THE TERMINAL
	LTM
	TAD (6041      /
	LTM           /
	SUF
	ION
	JMP TTYTST     /
/- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
RET4,	CLA CLL               / >
	TAD (RET5
	DCA ENDTRP
	SUF
	ION
	JMP MDTST      /TEST ALL VALUES FOR MD DATA
/- - - - - - - - - - - - - - - - - - - - - - - - - -
RET5,	SZA CLA               /SHOULD NOT TRAP
	JMS MDERR
	JMS RDFTST     /NOW EXERCIZE RDF IN USER MODE
	ISZ COUNT      /SELECT NEXT TARGET FIELD
	JMP LOOP5     /NOT DONE YET
	JMP LOOP0      /START OVER AGAIN

COPY,	0
	TAD FIELDS
	CIA
	IAC
	SNA
	JMP I COPY   /ONLY 4K
	DCA COUNT
COPY1,	CMA
	DCA 10
	CMA
	DCA 11
	TAD COUNT
	TAD FIELDS
	CLL RAL
	RTL
	TAD (CDF
	DCA YCDF
	TAD (-200
	DCA COUNT1
COPY2,	CDF 0
	TAD I 10
YCDF,	HLT
	DCA I 11
	ISZ COUNT1
	JMP COPY2
	TAD YCDF
	AND (70
	CLL RTR
	RAR
	TAD I (KK
	DCA I (KK
	CDF 0
	ISZ COUNT
	JMP COPY1
	JMP I COPY

/STATIC IOT TST FOR DM8E40 INSTRUCTIONS:
IOTTST,	0
	TAD (IOTLST-1 /SETUP LIST POINTER
	DCA 10
	TAD I 10       /FETCH FIRST IOT
IOT1,	DCA IOTX       /
	TAD (5252      /GET A TEST PATERN IN THE AC
IOTX,	HLT           /REPLACED BY THE IOT UNDER TEST
	JMP IOT2       /IOT DID NOT SKIP
	DCA AC        /REMEBER AC AFTER IOT
	TAD I 10       /GET SKIP FLAG
	SNA CLA               /SHOULD HE HAVE SKIPPED ?
	JMS ERR1      /NO, BUT HE DID !
	JMP IOT3       /GO CHECK AC EFFECTS
IOT2,	DCA AC        /REMEMBER AC
	TAD I 10       /GET SKIP FLAG
	SZA CLA               /SHOULD HE HAVE SKIPPED ?
	JMS ERR2      /YES, BUT HE DIDN'T !
IOT3,	TAD I 10       /GET AC-CHANGED FLAG
	SNA CLA               /SHOULD AC HAVE CHANGED ?
	JMP IOT4      /NO, GO CHECK THAT
	TAD I 10       /YES, MUST AC BE CLEAR NOW ?
	SNA CLA               /
	JMP IOT5      /NO, UNDEFINED AC NOW
	TAD AC        /YES, TEST AC
	SZA CLA               /ZERO ?
	JMS ERR3      /NO, IOT DID NOT CLA !
	JMP IOT5       /DONE ALL TESTS
IOT4,	TAD AC        /IF HERE AC SHOULD NOT HAVE CHANGED
	TAD (-5252     /TEST IF STILL OK
	SZA CLA               /
	JMS ERR4      /IOT SPOILED AC
IOT5,	TAD I 10       /GET NEXT IOT
	SZA           /END OF LIST ?
	JMP IOT1      /NO, TEST NEXT IOT
	JMS I [CDTOIF /TEST 6200
	JMP I IOTTST

PAGE
RDFTST,	0             /TEST RDF IN USER MODE
	JMS TRPALL
	TAD (RET6
	DCA ENDTRP
	TAD I (XCDF    /SET DATAFIELD TO
	CMA           /COMPLEMENT OF
	AND (70               /REAL FIELD
	TAD (CDF
	DCA KCDF
	TAD (-7
	DCA COUNT1     /CHANGE MAPPING
LOOP8,	TAD KCDF         /
	AND (70               /
	TAD COUNT1     /
	TAD (10               /
	LRM           /
	ISZ COUNT1     /
	JMP LOOP8     /
KCDF,	CDF 70
	SUF
	ION
	JMP TSTRDF
/- - - - - - - - - - - - - - - - - - - - - - - - - - - - -
RET6,	SZA CLA               /DID RDF TRAP ?
	JMS RDFER1    /YES, ERROR
	TAD KCDF       /COMPUTE CORRECT AC
	AND (70
	MQL
	MQA
	CMA
	AND (70
	CLL RTR
	RAR
	MQA
	CIA
	TAD AC        /GET VIRTUAL AC
	SZA CLA               / ?
	JMS RDFER2    /NO, AC WAS SPOILED !
	JMP I RDFTST   /RETURN

PAGE
/ERROR MESSAGE PROCESSORS:
INTERR,	CAF
	KIE
	JMS I [STRING
	TEXT /UNEXPECTED INTERRUPT/
	JMS I [CRLF
	TAD AC
	RMF
	ION
	JMP I 0

TRPERR,	0
	JMS I [STRING
	TEXT /TRAP REGISTER WRONG: (PC-1)=/
	TAD I 0
	JMS OCTOUT
	JMS I [STRING
	TEXT /, RTM=/
	TAD TRAPD
	JMS OCTOUT
	JMS I [CRLF
	JMP I TRPERR

RELERR,	0
	JMS I [STRING
	TEXT /RELOCATION ERROR, GOOD FIELD=/
	TAD COUNT
	TAD FIELDS
	JMS OCTOUT
	JMS I [STRING
	TEXT /, ACTUAL FIELD=/
	TAD AC
	JMS OCTOUT
	JMS I [CRLF
	JMP I RELERR

TERROR,	0
	TAD TRPTST
	JMS OCTOUT
	TAD I PTR
	SNA CLA
	JMP TER1
	JMS I [STRING
	TEXT / FAILED TO TRAP/
	JMP TER2
TER1,	JMS I [STRING
	TEXT /  DID  TRAP /
TER2,	JMS I [STRING
	TEXT / IN FIELD /
	TAD COUNT
	TAD FIELDS
	AND (7
	TAD ("0
	JMS TYPE
	JMS I [CRLF
	JMP I TERROR

PAGE
UERROR,	0
	TAD TRPTST
	JMS OCTOUT
	TAD I PTR
	SZA CLA
	JMP UER1
	JMS I [STRING
	TEXT / DID NOT UNTRAP/
	JMP UER2
UER1,	JMS I [STRING
	TEXT / DID UNTRAP/
UER2,	JMS I [STRING
	TEXT / IN FIELD /
	TAD COUNT
	TAD FIELDS
	AND (7
	TAD ("0
	JMS TYPE
	JMS I [CRLF
	JMP I UERROR

MDERR,	0
	JMS I [STRING
	TEXT /TRAPPED ON MEMORY DATA /
	TAD Q
	JMS OCTOUT
	JMS I [CRLF
	JMP I MDERR

ERR1,	0
	TAD I (IOTX
	JMS I [OCTOUT
	JMS I [STRING
	TEXT / WRONGLY SKIPPED/
	JMS I [CRLF
	JMP I ERR1

ERR2,	0
	TAD I [IOTX
	JMS I [OCTOUT
	JMS I [STRING
	TEXT / FAILED TO SKIP/
	JMS I [CRLF
	JMP I ERR2

ERR3,	0
	TAD I [IOTX
	JMS I [OCTOUT
	JMS I [STRING
	TEXT / FAILED TO CLEAR AC/
	JMS I [CRLF
	JMP I ERR3

ERR4,	0
	TAD I [IOTX
	JMS I [OCTOUT
	JMS I [STRING
	TEXT / SPOILED THE AC/
	JMS I [CRLF
	JMP I ERR4
PAGE

RDFER1,	0
	JMS I [STRING
	TEXT /RDF DID TRAP !/
	JMS I [CRLF
	JMP I RDFER1

RDFER2,	0
	JMS I [STRING
	TEXT /RDF RETURNED WRONG ANSWER: /
	TAD AC
	JMS I [OCTOUT
	JMS I [CRLF
	JMP I RDFER2

PAGE
TRPALL,	0              /SUBROUTINE TO SET ALL BITS
	TAD (-100       /IN THE TRAP MEMORY (EXCEPT 600X)
	DCA TRPCNT
TRP1,	TAD TRPCNT
	TAD (100        /MAKE IT POSITIVE
	CLL RAL
	RTL
	LTM             /SET TO TRAP
	ISZ TRPCNT       /DONE ?
	JMP TRP1        /NO
	TAD (6001        /UNTRAP ION FOR 6215, 6225
	LTM             /
	JMP I TRPALL     /YES, RETURN
UTRALL,	0              /SUBROUTINE TO UNTRAP ALL DEVICE CODES
	TAD (-100
	DCA TRPCNT     /
UTR1,	TAD TRPCNT
	TAD (100       /MAKE IT POTIVE
	CLL RAL
	RTL
	IAC            /SET UNTRAP BIT
	LTM
	ISZ TRPCNT     /DONE ?
	JMP UTR1      /NO
	JMP I UTRALL   /YES, RETURN

TRPCNT,	0

CDTOIF,	0      /TEST CDTOIF INSTRUCTION
	TAD FIELDS     /FOR ALL AVAILABLE FIELDS
	CIA
	DCA COUNT1     /
CDT1,	TAD COUNT1
	TAD FIELDS     /MAKE POSITIVE FIELD NUMBER
	CLL RAL
	RTL
	TAD [CIF
	DCA CDT3       /
	TAD CDT3
	CMA           /MAKE COMPLEMENTARY CDF
	AND [70
	TAD [CDF
	DCA CDT2
CDT2,	HLT           /CDF
CDT3,	HLT           /CIF
	JMS CDTF       /DO CDTOIF IN SOME FIELD
	RDF           /READ DATA FIELD
	CDF 0         /RESET DF
	CIA
	TAD CDT3       /AND COMPARE WITH PREVIOUS
	AND [70               /INSTRUCTION FIELD
	SZA CLA               /OK ?
	JMS CDTERR    /NO, CDTOIF DID NOT WORK
	ISZ COUNT1     /TRY NEXT FIELD
	JMP CDT1
	JMP I CDTOIF   /END OF TEST

CRLF,	0
	TAD (215
	JMS TYPE
	TAD (212
	JMS TYPE
	JMP I CRLF

STRING,	0
	TAD I STRING
	BSW
	JMS BYTE
	TAD I STRING
	ISZ STRING
	JMS BYTE
	JMP STRING+1

BYTE,	0
	AND (77
	SNA
	JMP I STRING
	TAD (240
	AND (77
	TAD (240
	JMS TYPE
	JMP I BYTE

OCTOUT,	0
	RAL
	JMS DIGIT
	JMS DIGIT
	JMS DIGIT
	JMS DIGIT
	CLA
	JMP I OCTOUT

DIGIT,	0
	RAL
	RTL
	DCA OCTEMP
	TAD OCTEMP
	AND (7
	TAD ("0
	JMS TYPE
	TAD OCTEMP
	JMP I DIGIT

OCTEMP,	0

PAGE
INIT,	0
	JMS I [STRING
	TEXT /HIGHEST FIELD # ? /
	KSF
	JMP .-1
	KRB
	TLS
	TSF
	JMP .-1
	AND (7
	IAC
	DCA FIELDS
	JMS I [CRLF
	JMP I INIT

CDTERR,	0
	JMS I [STRING
	TEXT /CDTOIF FAILED IN FIELD /
	TAD COUNT1
	TAD FIELDS
	AND [7
	TAD ["0
	JMS TYPE
	JMS I [CRLF
	JMP I CDTERR

TYPE,	0
	TLS
	TSF
	JMP .-1
	CLA
	KSF
	JMP I TYPE
CTRLQ,	TAD (7600
	KRS
	TAD (-7603
	SNA
	JMP I (7600
	TAD (3-23
	SNA CLA
	JMP CTRLS
	KCC
	JMP I TYPE
CTRLS,	KCC
	KSF
	JMP .-1
	JMP CTRLQ
PAGE
/THE IOT TABLE. THE FORMAT IS: IOT;SHOULD-TRAP-IF-TRAPPED;SHOULD-TRAP-
/IF-UNTRAPPED. THE TABLE ENDS WITH IOT=0

          Y=7777
          N=0000
TABLE,	6000;Y;N
	6006;N;N      /SGT
IFDEF PRODUCTION <
	6010;Y;N
	6020;Y;N
	6030;Y;N
	6040;Y;N
	6050;Y;N
	6060;Y;N
	6070;Y;N
	6100;Y;N
	6110;Y;N
	6120;Y;N
	6130;Y;N
	6140;Y;N
	6150;Y;N
	6160;Y;N
	6170;Y;N      / >
	6200;Y;Y      /CDTOIF
	6201;Y;N      /CDF 0
	6202;Y;N      /CIF 0
	6203;Y;N      /CDF CIF 0
	6204;Y;Y      /CINT
	6205;Y;Y       /RTM
	6206;Y;Y
	6207;Y;Y
	6210;Y;Y
	6211;Y;N       /CDF 10
	6212;Y;N       /CIF 10
	6213;Y;N       /CDF CIF 10
	6214;N;N       /RDF
	6215;Y;Y       /SKME
	6216;Y;Y
	6217;Y;Y
	6220;Y;Y
	6221;Y;N       /CDF 20
	6222;Y;N       /CIF 20
	6223;Y;N       /CDF CIF 30
	6224;N;N       /RIF
	6225;Y;Y       /SKMM
	6226;Y;Y
	6227;Y;Y
	6230;Y;Y
	6231;Y;N       /CDF 30
	6232;Y;N       /CIF 30
	6233;Y;N       /CDF CIF 0
	6234;Y;Y
	6235;Y;Y
	6236;Y;Y
	6237;Y;Y
	6240;Y;Y
	6241;Y;N       /CDF 40
	6242;Y;N       /CIF 40
	6243;Y;N       /CDF CIF 40
	6244;Y;Y
	6245;Y;Y
	6246;Y;Y
	6247;Y;Y
	6250;Y;Y
	6251;Y;N       /CDF 50
	6252;Y;N       /CIF 50
	6253;Y;N       /CDF CIF 50
	6254;Y;Y
	6255;Y;Y
	6256;Y;Y
	6257;Y;Y
	6260;Y;Y
	6261;Y;N      /CDF 60
	6262;Y;N      /CIF 60
	6263;Y;N      /CDF CIF 60
	6264;Y;Y
	6265;Y;Y
	6266;Y;Y
	6267;Y;Y
	6270;Y;Y
	6271;Y;N      /CDF 70
	6272;Y;N      /CIF 70
	6273;Y;N      /CDF CIF 70
	6274;Y;Y
	6275;Y;Y
	6276;Y;Y
	6277;Y;Y
IFDEF PRODUCTION <
	6300;Y;N
	6310;Y;N
	6320;Y;N
	6320;Y;N
	6330;Y;N
	6340;Y;N
	6350;Y;N
	6360;Y;N
	6370;Y;N
	6400;Y;N
	6410;Y;N
	6420;Y;N
	6430;Y;N
	6440;Y;N
	6450;Y;N
	6460;Y;N
	6470;Y;N
	6500;Y;N
	6510;Y;N
	6520;Y;N
	6530;Y;N
	6540;Y;N
	6550;Y;N
	6560;Y;N
	6570;Y;N
	6600;Y;N
	6610;Y;N
	6620;Y;N
	6630;Y;N
	6640;Y;N
	6650;Y;N
	6660;Y;N
	6670;Y;N
	6700;Y;N
	6710;Y;N
	6720;Y;N
	6730;Y;N
	6740;Y;N
	6750;Y;N
	6760;Y;N
	6770;Y;N       / >
	7402;Y;Y       /HLT
	7404;Y;Y       /OSR
	0             /END OF TABLE

/LIST FOR STATIC IOT TEST. EACH ENTRY CONSISTS OF
/IOT-CODE, SHOULD-SKIP, MAY-CHANGE-AC, (SHOULD-CLEAR-AC).
/THE LAST ELEMENT IS ONLY NEEDED IF MAY-CHANGE-AC IS YES.
IOTLST,	6200;N;N
	CMME;N;N
	RTM;N;Y;N
	SKME;N;N
	SKMM;Y;N
	LTM;N;Y;Y
	LRM;N;Y;Y
	SMME;N;N
	SKME;Y;N
	SKMM;Y;N
	RTM;N;Y;N
	LTM;N;Y;Y
	LRM;N;Y;Y
	0
$